西南石油大学学报(自然科学版) ›› 1994, Vol. 16 ›› Issue (1): 110-114.DOI: 10.3863/j.issn.1000-2634.1994.01.017

• 基础科学 • Previous Articles     Next Articles

Effects Of Vacuum Saturation Method on Electrical Resistivity Measurement of Rock Samples

Zhang Kaihong Chen Fuxuan Chen Yijian   

  1. Completion Technique Center
  • Received:1993-05-11 Revised:1900-01-01 Online:1994-02-20 Published:1994-02-20

Abstract: This paper present a method to replace in a process of vacuum saturation the residual air with injecting CO2 gas so as to reduce the error in the measurement of electrical resistivity.The results of a series of experiments show that this method has improved the conventional method of vacuum saturation and almost increased the accuracy of the measurement by 10%.In addition,a better experimental process is also suggested in this paper.

Key words: Core, Electical resistivity, residual air, in jesting CO2, vacuum saturation

CLC Number: