Abstract:

A high-sulfur natural gas purification plant can process 120×108 m3 feed gas,in which the mole fraction of H2S and
CO2 reach 14% and 8%,respectively. Production facilities and equipment in the high-sulfur natural gas purification plant are
at severe risk of corrosion for the high content of acidic components and large capacity load. Considering the characteristics of
the plant,we adopted the inductors(DG–9500)to monitor the corrosion in 14 detection points distributed in desulfurization,
dehydration,sulfur recovery,tail gas treatment,sour water stripping unit. Through a one-year corrosion detection,we obtained
the degree of corrosion in the process nodes,combined which with the corrosion coupon results,we found the corrosion weaknesses
of this gas purification plant. The results showed that the corrosion mainly occurred in the amine regeneration system,
sulfur recovery systems and chilled water cooling systems. The corrosion types include general corrosion,localized corrosion
and pitting. It was also found that the results obtained from inductive probes and corrosion coupons were almost the same,
which indicates that the former detective method can be used to monitor the corrosion conditions effectively in the high-sulfur
natural gas plants. The research provides an important basis for corrosion detection in the high-sulfur purification plants.

Key words: high-sulfur gas fields, purification, on-line corrosion, corrosion monitoring, corrosion coupons