大理大学学报 ›› 2022, Vol. 7 ›› Issue (2): 29-32.

• 药学 • 上一篇    下一篇

静脉用药调配中心自动化建设的应用与实践

汪子欣1,李 霞2,张 海2,邱 琳2,鲁晓男2,汪清桂2,古 云2*   

  1. (1.大理大学药学院,云南大理 671000;2.大理大学第一附属医院静脉用药调配中心,云南大理 671000)

  • 收稿日期:2021-08-16 修回日期:2021-10-23 出版日期:2022-02-15 发布日期:2022-03-28
  • 通讯作者: 古云,副主任药师,E-mail:156719002@qq.com。
  • 作者简介:汪子欣,硕士研究生,主要从事临床药学研究。
  • 基金资助:
    大理市科技计划项目(2020KGB016)

Application and Practice of Automation Construction of Pharmacy Intravenous Admixture Service

Wang Zixin1, Li Xia2, Zhang Hai2, Qiu Lin2, Lu Xiaonan2, Wang Qinggui2, Gu Yun2*   

  1. (1.College of Pharmacy, Dali University, Dali, Yunnan 671000, China; 2. Pharmacy Intravenous Admixture Services, The First Affiliated Hospital of Dali University, Dali, Yunnan 671000, China)

  • Received:2021-08-16 Revised:2021-10-23 Online:2022-02-15 Published:2022-03-28

摘要: 目的:探讨静脉用药调配中心(PIVAS)引进自动化设备对工作效率及质量的影响。方法:收集大理大学第一附属医院PIVAS启用自动化设备前后3个月工作效率和差错率数据进行统计分析,评价其应用效果。结果:每张医嘱排药时间由(4.93±0.82) s降至(2.20±0.61) s, 差错率由(1.16±0.23)‰降至(0.42±0.17)‰; 贴签时间由(3.14±0.68) s降至(1.01±0.53) s, 差错率由(0.92±0.43)‰降至(0.09±0.01)‰, 人员由6人降至4人;西林瓶每瓶剥盖时间由(1.01±0.31) s降至(0.87±0.11) s, 人员由4人降至1人;每瓶西林瓶、安瓿瓶配液时间分别由(3.93±1.37)、(3.04±1.21) s降至(2.71±0.74)、(2.54±0.39) s,差错率由(1.20±0.31)‰降至(0.24±0.04)‰;每瓶成品输液分拣、扫描打包时间由(15.75±2.11) s降至(5.42±1.77) s, 差错率由(3.15±0.21)‰降至(0.16±0.10)‰, 人员由7人降至4人。结论:PIVAS自动化建设在节省人力资源的同时,明显提高了工作效率和药学服务质量。

关键词:

">静脉用药调配中心;自动化建设;应用;实践

Abstract: Objective: To investigate the influence of automation equipment on work efficiency and quality in pharmacy intravenous admixture services (PIVAS). Methods: The data of the efficiency and the error rate of PIVAS in the First Affiliated Hospital of Dali University before and after 3 months of automation equipment application were collected and analyzed, and then its application effect was evaluated. Results: The filling time of each prescription had decreased from (4.93±0.82) s to (2.20±0.61) s, and the error rate decreased from (1.16±0.23) ‰ to (0.42±0.17) ‰. The labeling time had decreased from (3.14±0.68) s to (1.01±0.53) s, the error rate decreased from (0.92±0.43) ‰ to (0.09±0.01) ‰, and the personnel reduced from 6 to 4 persons. The decapping time of each bottle of penicillin had decreased from (1.01±0.31) s to (0.87±0.11) s, and the personnel reduced from 4 persons to 1 person.The preparation times of each bottle of penicillin and ampoule had decreased from (3.93±1.37) s and (3.04±1.21) s to (2.71±0.74) s and (2.54±0.39) s respectively, the error rate decreased form(1.20±0.31) ‰ to (0.24±0.04) ‰. The sorting, scanning and packing time of infusion had decreased from (15.75±2.11) s to (5.42±1.77) s, the error rate decreased from (3.15±0.21) ‰ to (0.16±0.10) ‰, and the personnel reduced from 7 to 4 persons. Conclusion:The automation construction of PIVAS not only saves human resources, but also significantly improves the work efficiency and pharmaceutical care quality.

Key words: font-family:Times New Roman, ">pharmacy intravenous admixture servicesfont-family:Times New Roman, ">;font-family:Times New Roman, "> automation constructionfont-family:Times New Roman, ">;font-family:Times New Roman, "> applicationfont-family:Times New Roman, ">;font-family:Times New Roman, "> practice

中图分类号: