摘要: 目的:探讨静脉用药调配中心(PIVAS)引进自动化设备对工作效率及质量的影响。方法:收集大理大学第一附属医院PIVAS启用自动化设备前后3个月工作效率和差错率数据进行统计分析,评价其应用效果。结果:每张医嘱排药时间由(4.93±0.82 s降至(2.20±0.61 s 差错率由(1.16±0.23)‰降至(0.42±0.17)‰; 贴签时间由(3.14±0.68 s降至(1.01±0.53 s 差错率由(0.92±0.43)‰降至(0.09±0.01)‰, 人员由6人降至4人;西林瓶每瓶剥盖时间由(1.01±0.31 s降至(0.87±0.11 s 人员由4人降至1人;每瓶西林瓶、安瓿瓶配液时间分别由(3.93±1.37)、(3.04±1.21 s降至(2.71±0.74)、(2.54±0.39 s,差错率由(1.20±0.31)‰降至(0.24±0.04)‰;每瓶成品输液分拣、扫描打包时间由(15.75±2.11 s降至(5.42±1.77 s 差错率由(3.15±0.21)‰降至(0.16±0.10)‰, 人员由7人降至4人。结论:PIVAS自动化建设在节省人力资源的同时,明显提高了工作效率和药学服务质量。

关键词:

">静脉用药调配中心;自动化建设;应用;实践

Abstract: Objective To investigate the influence of automation equipment on work efficiency and quality in pharmacy intravenous admixture services PIVAS. Methods The data of the efficiency and the error rate of PIVAS in the First Affiliated Hospital of Dali University before and after 3 months of automation equipment application were collected and analyzed and then its application effect was evaluated. Results The filling time of each prescription had decreased from 4.93±0.82 s to 2.20±0.61 s and the error rate decreased from 1.16±0.23 to 0.42±0.17 . The labeling time had decreased from 3.14±0.68 s to 1.01±0.53 s the error rate decreased from 0.92±0.43 to 0.09±0.01 ‰, and the personnel reduced from 6 to 4 persons. The decapping time of each bottle of penicillin had decreased from 1.01±0.31 s to 0.87±0.11 s and the personnel reduced from 4 persons to 1 person.The preparation times of each bottle of penicillin and ampoule had decreased from 3.93±1.37 s and 3.04±1.21 s to 2.71±0.74 s and 2.54±0.39 s respectively the error rate decreased form1.20±0.31 to 0.24±0.04 . The sorting scanning and packing time of infusion had decreased from 15.75±2.11 s to 5.42±1.77 s the error rate decreased from 3.15±0.21 to 0.16±0.10 ‰, and the personnel reduced from 7 to 4 persons. ConclusionThe automation construction of PIVAS not only saves human resources but also significantly improves the work efficiency and pharmaceutical care quality.

Key words: font-family:Times New Roman, ">pharmacy intravenous admixture servicesfont-family:Times New Roman, ">;font-family:Times New Roman, "> automation constructionfont-family:Times New Roman, ">;font-family:Times New Roman, "> applicationfont-family:Times New Roman, ">;font-family:Times New Roman, "> practice