大理大学学报 ›› 2024, Vol. 9 ›› Issue (8): 41-45.DOI: 10. 3969 / j. issn. 2096-2266. 2024. 08. 007

• 药学 • 上一篇    下一篇

基于红外光谱结合化学计量学的美洲大蠊精制物CⅡ-3#br# 无损质量评价方法

周姣姣1,夏从龙2,李文璨1,王艳平1,李 伟1,何正春2*   

  1. (1.湘潭市中心医院药学部,湖南湘潭 411100; 2.大理大学药学院,云南大理 671000)
  • 收稿日期:2022-09-09 修回日期:2022-10-12 出版日期:2024-08-15 发布日期:2024-08-12
  • 通讯作者: 何正春,副教授,E-mail:hezhengchun2006@163.com。
  • 作者简介:周姣姣,主管中药师,主要从事药物化学研究。
  • 基金资助:
    中国药学会科技开发中心科普项目(CMEI2024KPYJ001176);湘潭市医学科研项目(2023-xtyx-54);国家自然
    科学基金项目(81660605)

Nondestructive Quality Evaluation of CⅡ- 3 Extract from Periplaneta americana Based on Infrared#br# Spectroscopy Combined with Chemometrics

Zhou Jiaojiao1, Xia Conglong2, Li Wencan1, Wang Yanping1, Li Wei1, He Zhengchun2*   

  1. (1. Department of Pharmacy, Xiangtan Municipal Central Hospital, Xiangtan, Hunan 411100, China; 2. College of Pharmacy,
    Dali University, Dali, Yunnan 671000, China)
  • Received:2022-09-09 Revised:2022-10-12 Online:2024-08-15 Published:2024-08-12

摘要: 目的:以美洲大蠊精制物CⅡ-3为研究对象,基于红外光谱结合化学计量学建立其品质无损的简易评价方法。方法:
采用红外光谱法建立10批CⅡ-3样品的红外光谱,并进行基线矫正、纵坐标归一化和15点平滑等预处理方法优化光谱图;运
用Origin 9.1软件对光谱数据进行表征和解析,建立10批CⅡ-3样品的指纹图谱,并进行相似度分析和主成分分析。结果:10
批CⅡ-3样品红外光谱的官能团区主要特征峰为3 300、2 960、2 930、1 660、1 630、1 550、1 450、1 390 cm-1,指纹区主要特征峰
为1 240、1 080、621、546 cm-1。不同批次CⅡ-3样品红外光谱的峰形、峰位和峰强相似,相关系数均在0.960以上。主成分分析
结果显示10批CⅡ-3样品聚为一类。结论:该方法操作简单、专属性强、不破坏样品,可实现CⅡ-3样品的无损质量评价。

关键词: 美洲大蠊, CⅡ-3, 红外光谱, 相似度分析, 主成分分析, 无损质量评价

Abstract: Objective: To establish a simple and nondestructive evaluation method of CⅡ-3 extract from Periplaneta americana
based on infrared spectrum and chemometrics. Methods: Infrared spectra of 10 batches of CⅡ-3 samples were established by infrared
spectroscopy, and the spectra were optimized by baseline correction, ordinate normalization and 15-point smoothing. Origin 9.1
software was used to characterize and analyze the spectral data, and the fingerprints of 10 batches of CⅡ-3 samples were established,
and similarity analysis and principal component analysis were performed. Results: The main characteristic peaks of the functional
group region in infrared spectra of 10 batches of CⅡ-3 samples were 3 300, 2 960, 2 930, 1 660, 1 630, 1 550, 1 450, 1 390 cm-1. The
main characteristic peaks in fingerprint region were 1 240, 1 080, 621, 546 cm-1. The peak shape, position and intensity of infrared
spectra were similar among different batches, and the correlation coefficients were all above 0.960. The results of principal component
analysis showed that 10 batches of samples were clustered into one category. Conclusion: The method has the advantages of simple
operations, strong specificity, no damage to the sample, and can be used for the quality evaluation for CⅡ-3 samples.

Key words: Periplaneta americana, CⅡ-3, infrared spectroscopy, similarity analysis, principal component analysis, nondestructive
quality evaluation

中图分类号: