西南石油大学学报(自然科学版)

• 石油机械工程 • 上一篇    下一篇

基于管柱声场模型的油井动液面检测新方法

周伟1 *,贾威2,郭小渝3,李太福1,易军1   

  1. 1. 重庆科技学院智能油气田研究所,重庆沙坪坝401331
    2. 西安石油大学电子工程学院,陕西西安710065
    3. 重庆理工大学电子信息与自动化学院,重庆沙坪坝400054
  • 出版日期:2015-08-01 发布日期:2015-08-01
  • 通讯作者: 周伟,E-mail:zhouw1985@163.com
  • 基金资助:

    国家自然科学基金(51404051);重庆市科技人才项目(cstc2013kjrc qnrc40008);重庆市教委科学技术研究项目(KJ1401326)。

A New Method for Oil Well Dynamic Fluid Level Detection Based on the Column Sound Field Model

Zhou Wei1*, Jia Wei2, Guo Xiaoyu3, Li Taifu1, Yi Jun1   

  1. 1. Research Institute of Intelligent Oil & Gas Field,Chongqing University of Science & Technology,Shapingba,Chongqing 401331,China
    2. College of Electronic Engineering,Xi′ an Shiyou University,Xi′ an,Shaanxi 710065,China
    3. College of Electronic Information & Automation,Chongqing University of Technology,Shapingba,Chongqing 400054,China
  • Online:2015-08-01 Published:2015-08-01

摘要:

针对传统回波法测油井动液面存在回波信号弱、干扰噪音大和液面波辨识难等问题,提出一种基于管柱声场
模型的油井动液面检测方法。受管乐器声乐频率可反映乐管长度的启发,利用管道声学理论对典型的管柱结构进行
分析,借助管柱的声场特性和管内空气柱的共振原理,建立油井动液面深度与管内声场固有频率的关系,再通过快速
傅立叶变换测定管内声场的固有频率,从而获得管内动液面深度。实验结果表明,提出的新方法验证了管柱空气共振
频率和动液面深度的关系,能较精确地得到管内液面深度,相对误差在2% 以内,为精确检测油井动液面深度提供了
一种新途径。

关键词: 动液面, 检测, 固有频率, 声场模型, 快速傅立叶变换

Abstract:

It is important to measure the depth of dynamic liquid level of oil well in order to set reasonable oil extraction
technology. In this paper,we proposed a detection method of oil well dynamic fluid level based on the sound field model of
the column,in order to solve the problem of weak echo signal,large noise disturbance and difficult identification of liquid
level wave in the traditional echo method. In this method,the typical string structure can be analyzed with the pipeline acoustic
theory. Moreover,the relationship between the well dynamic fluid level depth and the natural frequency of the tube sound field
is established,according to the sound field characteristic of the column and resonance theory of tube air column,inspired by the
fact that the vocal frequency of wind instrument can reflect the acoustic pipe length. Then we measured the natural frequency
of the sound field in tube by Fast Fourier Transform(FFT),and liquid level depth of tube will be obtained. The experimental
results confirm the relationships between the string air resonance frequency and dynamic liquid level,and show that the tube
liquid level depth is more accurate within 2% relative error by using this method which provides a new way for the accurate
detection of the well dynamic fluid level depth.

Key words: dynamic fluid level, detection, natural frequency, sound field model, FFT