大理大学学报 ›› 2023, Vol. 8 ›› Issue (4): 69-72.

• 临床医学 • 上一篇    下一篇

E光技术联合类人胶原蛋白修复敷料治疗面部敏感性皮肤患者疗效观察

陈文秋,庞 勤,赵 宇,李 涛,林祥弘,孙素姣   

  1. 1.大理大学第一附属医院,云南大理 6710002.昆明菲岫皮肤医疗美容诊所,昆明 6500003.昆明天权文化传播有限公司,昆明 650000

  • 收稿日期:2022-09-26 出版日期:2023-04-15 发布日期:2023-04-25
  • 通讯作者: 孙素姣,副教授,E-mail:sunsujiaode@163.com。
  • 作者简介:陈文秋,硕士研究生,主要从事损容性皮肤病相关研究。
  • 基金资助:

    云南省地方本科高校基础研究联合专项资金项目(202001BA070001-64);大理大学第一附属医院学科队伍建设项目(DFYZD2022-11

Clinical Effect of ELOS Technique Combined with Human-Like Collagen Repair Dressing in the Treatment of Patients with Facial Sensitive Skin

Chen WenqiuPang QinZhao YuLi TaoLin XianghongSun Sujiao   

  1. 1. The First Affiliated Hospital of Dali UniversityDaliYunnan 671000China2. Kunming Feixiu Skin Medical and Beauty ClinicKunming 650000China3. Kunming Tianquan Culture Communication Co.Ltd.Kunming 650000China

  • Received:2022-09-26 Online:2023-04-15 Published:2023-04-25

摘要:

目的:评价Emax光电射频治疗仪联合类人胶原蛋白修复敷料治疗面部敏感性皮肤患者的临床疗效。方法:对所有纳入研究者使用Emax光电射频治疗仪治疗4次,同时配合使用类人胶原蛋白修复敷料后,记录患者VISIA皮肤检测仪下红斑区分值、乳酸刺激试验评分及阳性率、不良反应发生情况和患者主观满意度。结果:患者接受4次治疗后,红斑区分值和乳酸刺激试验评分显著降低,乳酸刺激试验阳性率由治疗前的100.00%降低至20.00%,差异有统计学意义(P<0.05);患者总体满意率为96.67%,对治疗具有较高的满意度;除1例患者治疗后出现皮肤轻度水肿、红斑外,其他患者未出现瘙痒、色素沉着等不良反应。结论:Emax光电射频治疗仪联合类人胶原蛋白修复敷料可明显改善敏感性皮肤的红斑反应,值得临床推广。

关键词:

"> font-size:10.5pt, ">敏感性皮肤, Emax光电射频治疗仪, 类人胶原蛋白修复敷料

Abstract:

ObjectiveTo evaluate the clinical efficacy of E-max photoelectric radiofrequency therapeutic instrument combined with human-like collagen repair dressing in the treatment of patients with facial sensitive skin. MethodsAll enrolled subjects received 4 treatments with E-max photoelectric radiofrequency therapeutic instrument and were simultaneously accompanied by the use of human collagen repair dressing. The erythema distinction value under VISIA skin detectorthe score and positive rate of lactic stimulation testthe occurrence of adverse reactions and patients' subjective satisfaction were recorded. ResultsAfter 4 treatmentsthe erythema distinction value and score of lactate stimulation test were significantly decreasedand the positive rate of lactate stimulation test was reduced from 100.00% before treatment to 20.00%with statistical significance P<0.05. The overall subjective satisfaction rate of patients was 96.67%indicating a high degree of satisfaction with treatment. No adverse reactions such as pruritus and pigmentation were observed in other patients except for 1 patient with mild skin edema and erythema after treatment. ConclusionE-max photoelectric radiofrequency therapeutic combined with human-like collagen repair dressing can obviously improve the erythema reaction of sensitive skinwhich is worthy of clinical promotion.

Key words:

"> font-size:10.5pt, ">sensitive skin, E-max photoelectric radiofrequency therapeutic instrument, human-like collagen repair dressing

中图分类号: