Abstract: By the experiment of the postmixed abrasive jet cleaning oil tube coating, it was concluded that the efficiency of the postmixed abrasive jet cleaning oil tube coating was related to nozzle diameter, standoff distance, jet angle and diameter of abrasivegrain, that the efficiency of the postmixed abrasive jet cleaning oil tube coating increased with the diameter of nozzle, the opti-mum value of standoff distance is 250 mm, of jet angle is 90 degree and of grain diameter is 0.8 mm.