Influences of Porosity Error on Electrical Properties of Rotk and Updating Formula as Well as Correction Charts

Zhang Kai-hong 1 Chen Yi-jian1 Chen Fu-xuan2

  

  1. 1.Center of Well Completion Techniques 2. Dept, of Exploration
  • Received:1994-12-19 Revised:1900-01-01 Online:1995-08-20 Published:1995-08-20
  • Contact: Zhang Kai-hong

Abstract: Error of porosity has a great influence upon water saturation (S,.)and saturation expo-nent u.,may be free from cement factor correction,while it is necessary for those with a poeosity less than 20%to have a water saturation and saturation exponent factor correction. When the error of porosity is greater than士0. 5 p. u.,it is necessary for the samples with a poros-ity less than 15%to have a cement factor correction, and all the samples to make a water saturation and saturation exponent correction.

Key words: Porosity, Rock electrical parameter, Cement factor, Water saturation, Saturation exponent, Error correction